Brookforge swimming pool engineers

Swimming Pool Dehumidifiers

Price-less Promise

Calorex Dehumidifiers

Calorex
Calorex Delta - A Unique Multifunctional Single Unit Offering Immense Flexibility

Calorex DeltaThe ultimate environmental control system - designed specifically to take full control of the whole indoor environment and pool water heating.

The Delta is an excellent system for use with distribution ductwork, automatically controlling:

  • Humidity Levels
  • Air Temperature
  • Pool Water Temperature
  • Ventilation

Each Delta is an extremely energy efficient unit designed and built specifically to suit each pool project. A combination of its compact design and optional positions of ductwork spigots and access panels, establishes the Delta as the ultimate equipment in its class.

Delta features & Benefits:

  • Dual Mode Heat Recovery
  • Twin Fan System
  • Ozone Friendly
  • Low Running Costs
  • Compact Design
  • Custom Built to Suit Individual Projects
  • Optional Configurations
  • Full Service Back-Up
  • BMS Compatibility Option

Please note, all Deltas require a sufficient supply of electricity and low pressure hot water - please see our range of dedicated system boilers.

Please see Delta Technical Info at the foot of the page.

Delta - Options Galore

The Calorex Delta now offers an incredible range of units, both in capacity and adaptability.

Having listened to our valued Customer's comments, all Deltas can now ne built to suit almost every plant room scenario. The Delta system now offers immense flexibility.

For your Information:

  • Delta 4 and above are available with Top, Bottom or Horizontal outlet at either end of the unit, to suit any plant room layout.
  • In addition to the successful Delta 14 comes the Delta 16 - Ideally suited for the larger commercial project, these unique work horses also offer extreme flexibility regarding plant room layouts.
  • Delta 14 & 16 fresh/exhaust air spigots can also be on either side if required.

 

Calorex
Calorex Delta - Top Outlet

CODE Description
D1/1/T Calorex Delta 1 - Top Outlet, 1-Phase
Please Call for Lowest Price
D2/1/T Calorex Delta 2 - Top Outlet, 1-Phase
Please Call for Lowest Price
D4/1/T Calorex Delta 4 - Top Outlet, 1-Phase
Please Call for Lowest Price
D6/1/T Calorex Delta 6 - Top Outlet, 1-Phase
Please Call for Lowest Price
D1/3/T Calorex Delta 1 - Top Outlet, 3-Phase
Please Call for Lowest Price
D2/3/T Calorex Delta 2 - Top Outlet, 3-Phase
Please Call for Lowest Price
D4/3/T Calorex Delta 4 - Top Outlet, 3-Phase
Please Call for Lowest Price
D6/3/T Calorex Delta 6 - Top Outlet, 3-Phase
Please Call for Lowest Price
D8/3/T Calorex Delta 8 - Top Outlet, 3-Phase
Please Call for Lowest Price
D10/3/T Calorex Delta 10 - Top Outlet, 3-Phase
Please Call for Lowest Price
D12/3/T Calorex Delta 12 - Top Outlet, 3-Phase
Please Call for Lowest Price
D14/3/T Calorex Delta 14 - Top Outlet, 3-Phase
Please Call for Lowest Price
D16/3/T Calorex Delta 16 - Top Outlet, 3-Phase
Please Call for Lowest Price

 

Calorex
Calorex Delta - Bottom Outlet

CODE Description
D1/1/B Calorex Delta 1 - Bottom Outlet, 1-Phase
Please Call for Lowest Price
D2/1/B Calorex Delta 2 - Bottom Outlet, 1-Phase
Please Call for Lowest Price
D4/1/B Calorex Delta 4 - Bottom Outlet, 1-Phase
Please Call for Lowest Price
D6/1/B Calorex Delta 6 - Bottom Outlet, 1-Phase
Please Call for Lowest Price
D1/3/B Calorex Delta 1 - Bottom Outlet, 3-Phase
Please Call for Lowest Price
D2/3/B Calorex Delta 2 - Bottom Outlet, 3-Phase
Please Call for Lowest Price
D4/3/B Calorex Delta 4 - Bottom Outlet, 3-Phase
Please Call for Lowest Price
D6/3/B Calorex Delta 6 - Bottom Outlet, 3-Phase
Please Call for Lowest Price
D8/3/B Calorex Delta 8 - Bottom Outlet, 3-Phase
Please Call for Lowest Price
D10/3/B Calorex Delta 10 - Bottom Outlet, 3-Phase
Please Call for Lowest Price
D12/3/B Calorex Delta 12 - Bottom Outlet, 3-Phase
Please Call for Lowest Price
D14/3/B Calorex Delta 14 - Bottom Outlet, 3-Phase
Please Call for Lowest Price
D16/3/B Calorex Delta 16 - Bottom Outlet, 3-Phase
Please Call for Lowest Price

 

Calorex
Calorex Delta - End Outlet

CODE Description
D1/1/E Calorex Delta 1 - End Outlet, 1-Phase
Please Call for Lowest Price
D2/1/E Calorex Delta 2 - End Outlet, 1-Phase
Please Call for Lowest Price
D4/1/E Calorex Delta 4 - End Outlet, 1-Phase
Please Call for Lowest Price
D6/1/E Calorex Delta 6 - End Outlet, 1-Phase
Please Call for Lowest Price
D1/3/E Calorex Delta 1 - End Outlet, 3-Phase
Please Call for Lowest Price
D2/3/E Calorex Delta 2 - End Outlet, 3-Phase
Please Call for Lowest Price
D4/3/E Calorex Delta 4 - End Outlet, 3-Phase
Please Call for Lowest Price
D6/3/E Calorex Delta 6 - End Outlet, 3-Phase
Please Call for Lowest Price
D8/3/E Calorex Delta 8 - End Outlet, 3-Phase
Please Call for Lowest Price
D10/3/E Calorex Delta 10 - End Outlet, 3-Phase
Please Call for Lowest Price
D12/3/E Calorex Delta 12 - End Outlet, 3-Phase
Please Call for Lowest Price
D14/3/E Calorex Delta 14 - End Outlet, 3-Phase
Please Call for Lowest Price
D16/3/E Calorex Delta 16 - End Outlet, 3-Phase
Please Call for Lowest Price

 

Calorex
Calorex Delta - Technical Information

Delta 1 Delta 2 Delta 4 Delta 6 Delta 8 Delta 10 Delta 12 Delta 14 Delta 16
Air Cooling Facility 3 3 3 3 3 3 3 3 3
Air Conditioning Facility 8 8 3 3 3 3 3 3 3
Electrical Power Consumption (kW) 3.18 3.84 3.94 5.12 6.25 7.80 9.35 14.50 18.00
Recommended Electrical Supply (Amps) - Single Phase 20 23 23 33 n/a n/a n/a n/a n/a
Recommended Electrical Supply (Amps) - Three Phase 11 12 9 12 14 16 20 40 60
Recommended Fuse Capacity (Amps) - Single Phase 30 30 30 45 n/a n/a n/a n/a n/a
Recommended Fuse Capacity (Amps) - Three Phase 15 15 13 15 20 25 30 60 72
Recommended Boiler Capacity (kW) 30 32 35 45 50 65 70 150 155
Weight (Unpacked) (Kg) 300 310 350 360 370 410 420 750 760

For guidance, circulation pumps for LPHW boiler water circuit are typically:

Delta 1 to 8 - Grundfos UPS 25-80 (or similar); Delta 10-16 Grundfos UPS 40-120 (or similar)

Calorex
Calorex Delta - Guideline Equipment Specification

  Delta 1 Delta 2 Delta 4 Delta 6 Delta 8 Delta 10 Delta 12 Delta 14 Delta 16
Domestic Pool Provisional Pool Surface Area (m²) Up to 70 70-75 75-80 85-100 100-130 130-160 160-180 180-360 360-420
Hotel/Club Pool Provisional Pool Surface Area (m²) Up to 60 60-65 65-75 75-90 90-155 115-145 145-165 165-330 330-385
Municipal Pool Provisional Pool Surface Area (m²) Up to 50 50-55 55-65 65-80 80-100 100-130 130-150 150-300 300-350

Please note all stated pool dehumidifier prices exclude VAT @ 20%

Need help? Want to order a swimming pool dehumidifier! then contact us : 01242 573572